R.M. Young Company

Voltage & Current Interfaces

05603C, 05631C, 05608C, 05638C

 

MODEL 05603C - WIND SENSOR INTERFACE - FOR USE WITH 05106
0-5 VDC OUTPUTS

The Wind Sensor Interface provides calibrated analog DC voltage signals for wind speed and wind direction.
Specifications
Power Requirement: 8-24 VDC (5 mA @ 12 VDC)
Temperature Range: -50 to 50°C (-58 to 122°F)
Inputs: Model 05106 Wind Monitor-MA
Outputs: 0 to 5.00 VDC
Wind Speed: 0 to 100 M/S, Wind Direction: 0 to 360°
Accuracy: ± 1% FS over temperature and supply voltage range.
Dimensions: 110 mm W x 75 mm H x 56 mm D (4.3 in W x 2.9 in H x 2.2 in D)
Mounting: U-bolt for vertical pipe 25-50mm (1- 2 in) Dia


MODEL 05631C - WIND LINE DRIVER - FOR USE WITH 05106
4-20 mA OUTPUTS

The Wind Line Driver converts signals from the wind sensor to 4 to 20 mA current loop values.
Specifications
Power Requirement: 12-30 VDC
Temperature Range: -50 to 50°C (-58 to 122°F)
Inputs: Model 05106 Wind Monitor-MA
Outputs: 4 to 20 mA
Wind Speed: 0 to 100 M/S, Wind Direction: 0 to 360°
Accuracy: ± 1% FS over temperature and supply voltage range.
Dimensions: 110 mm W x 75 mm H x 56 mm D (4.3 in W x 2.9 in H x 2.2 in D)
Mounting: U-bolt for vertical pipe 25-50mm (1- 2 in) Dia


05603C
Manual
05608C
Manual
05631C
Manual
05638C
Manual

 

 


MODEL 05608C - WIND SENSOR INTERFACE - FOR USE WITH 05108
0-5 VDC OUTPUTS

The Wind Sensor Interface provides calibrated analog DC voltage signals for wind speed and wind direction.
Specifications
Power Requirement: 8-24 VDC (5 mA @ 12 VDC)
Temperature Range: -50 to 50°C (-58 to 122°F)
Inputs: Model 05108 Wind Monitor-HD
Outputs: 0 to 5.00 VDC
Wind Speed: 0 to 100 M/S, Wind Direction: 0 to 360°
Accuracy: ± 1% FS over temperature and supply voltage range.
Dimensions: 110 mm W x 75 mm H x 56 mm D (4.3 in W x 2.9 in H x 2.2 in D)
Mounting: U-bolt for vertical pipe 25-50mm (1- 2 in) Dia


MODEL 05638C - WIND LINE DRIVER - FOR USE WITH 05108
4-20 mA OUTPUTS

The Wind Line Driver converts signals from the wind sensor to 4 to 20 mA current loop values.
Specifications
Power Requirement: 12-30 VDC
Temperature Range: -50 to 50°C (-58 to 122°F)
Inputs: Model 05108 Wind Monitor-HD
Outputs: 4 to 20 mA
Wind Speed: 0 to 100 M/S, Wind Direction: 0 to 360°
Accuracy: ± 1% FS over temperature and supply voltage range.
Dimensions: 110 mm W x 75 mm H x 56 mm D (4.3 in W x 2.9 in H x 2.2 in D)
Mounting: U-bolt for vertical pipe 25-50mm (1- 2 in) Dia

 

 

 

 
Ordering InformationModelPrice
WIND SENSOR INTERFACE / 0-5 VDC outputs 05608C$474.00
WIND LINE DRIVER / 4-20 mA Outputs 05638C$516.00
WIND SENSOR INTERFACE / 0-5 VDC outputs 05603C$466.00
WIND LINE DRIVER / 4-20 mA outputs 05631C$506.00
 
 
CABLE for 05603C / 5 conductor shielded 18446 $0.60/ft.
CABLE for 05631C / 2 pair shielded 18723 $0.66/ft.
CABLE for 05608C / 6 conductor shielded 18721 $1.20/ft.
CABLE for 05638C / 6 conductor shielded 18721 $1.20/ft.

Order Sensor Cable Here