R.M. Young Company

Current & Voltage Interfaces

05631C, 05603C

 
MODEL 05631C - WIND LINE DRIVER
4-20 mA OUTPUTS

The Wind Line Driver converts signals from the wind sensor to 4 to 20 mA current loop values.
Specifications
Power Requirement: 12-30 VDC
Temperature Range: -50 to 50°C (-58 to 122°F)
Inputs: YOUNG Wind Monitor
Outputs: 4 to 20 mA
Wind Speed: 0 to 100 M/S, Wind Direction: 0 to 360°
Accuracy: ± 1% FS over temperature and supply voltage range.
Dimensions: 110 mm W x 75 mm H x 56 mm D (4.3 in W x 2.9 in H x 2.2 in D)
Mounting: U-bolt for vertical pipe 25-50mm (1- 2 in) Dia


MODEL 05603C - WIND SENSOR INTERFACE
0-5 VDC OUTPUTS

The Wind Sensor Interface provides calibrated analog DC voltage signals for wind speed and wind direction.
Specifications
Power Requirement: 8-24 VDC (5 mA @ 12 VDC)
Temperature Range: -50 to 50°C (-58 to 122°F)
Inputs: YOUNG Wind Monitor
Outputs: 0 to 5.00 VDC
Wind Speed: 0 to 100 M/S, Wind Direction: 0 to 360°
Accuracy: ± 1% FS over temperature and supply voltage range.
Dimensions: 110 mm W x 75 mm H x 56 mm D (4.3 in W x 2.9 in H x 2.2 in D)
Mounting: U-bolt for vertical pipe 25-50mm (1- 2 in) Dia

 
Ordering InformationModelPrice
WIND SENSOR INTERFACE / 0-5 VDC outputs 05603C$402.00
WIND LINE DRIVER / 4-20 mA outputs 05631C$448.00
 
 
CABLE for 05063C / 5 conductor shielded 18446 $0.50/ft.
CABLE for 05631C / 2 pair shielded 18723 $0.60/ft.
Order Sensor Cable Here

Complies with applicable CE directives. Specifications subject to change without notice.